{"title":"Imperial","description":"\u003cp\u003eBrowse our complete range of genuine Imperial commercial kitchen parts and equipment. Find replacement parts for ranges, ovens, fryers, and cooking equipment.\u003c\/p\u003e","products":[{"product_id":"robertshaw-thermostat-rx-1-36-for-gas-fryer-max-temp-400-f-204-c-npt-1-4","title":"Millivolt Gas Fryer Thermostat 204C 1\/4 NPT RX-1-36 for Commercial Fryer","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Robertshaw RX-1-36 is a millivolt-type operating thermostat for commercial gas and electric fryers, controlling temperature between 200F and 400F (93C to 204C). It features a 36 inch capillary, a 9.5mm diameter probe measuring 123mm in length, and a 1\/4 inch NPT stuffing gland. One of the most widely used Robertshaw thermostat models in the foodservice industry, it crosses to a very broad range of fryer brands including Pitco, Imperial, American Range, Falcon and Dean. The part replaces Pitco references 60125401 and 60125402 among others.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eType: Millivolt operating thermostat\u003c\/li\u003e\n\u003cli\u003eTemperature Range: 200F to 400F (93C to 204C)\u003c\/li\u003e\n\u003cli\u003eCapillary Length: 36 inches (915mm)\u003c\/li\u003e\n\u003cli\u003eProbe Diameter: 9.5mm\u003c\/li\u003e\n\u003cli\u003eProbe Length: 123mm\u003c\/li\u003e\n\u003cli\u003eTank Gland: 1\/4 inch NPT\u003c\/li\u003e\n\u003cli\u003ePin Shape: D-shaped\u003c\/li\u003e\n\u003cli\u003eRotation Angle: 315 degrees\u003c\/li\u003e\n\u003cli\u003eCross References: Pitco 60125401, All Points 46-1272, Imperial 1175, Anets P8905-03, Royal Range 3113\u003c\/li\u003e\n\u003cli\u003eCondition: New\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCompatible Equipment\u003c\/h2\u003e\u003cp\u003eThis thermostat is compatible with the following commercial catering equipment:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePitco — SG fryer series (ref. 60125401 \/ 60125402)\u003c\/li\u003e\n\u003cli\u003eImperial — 1175 series, IF, IHR, IR\u003c\/li\u003e\n\u003cli\u003eAmerican Range — 11113, A50400\u003c\/li\u003e\n\u003cli\u003eAnets — 14VFS, 18EG, P8905-03\u003c\/li\u003e\n\u003cli\u003eFalcon — G1830, G1860 Dominator\u003c\/li\u003e\n\u003cli\u003eDean — 11E, 11G, 14E, 14G, 32G, 714G, 1212G, 1414G, 1818G, 2020G, 2424G, D-35, M-35, M-40GM\u003c\/li\u003e\n\u003cli\u003eRoyal Range — 3113\u003c\/li\u003e\n\u003cli\u003eBlodgett — Z1182151\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eNot sure if this fits your equipment? Contact us with your machine make, model and part number and we will confirm compatibility before you order.\u003c\/p\u003e\u003ch2\u003eSigns You Need To Replace This Part\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFryer oil will not reach or maintain the set cooking temperature\u003c\/li\u003e\n\u003cli\u003eBurner fires continuously and oil overheats past the dial setting\u003c\/li\u003e\n\u003cli\u003eErratic temperature swings during service affecting food quality\u003c\/li\u003e\n\u003cli\u003eThermostat dial is loose, stiff, or shows no response when turned\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhy Buy From LaunchCatering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUK stock - ready for fast dispatch\u003c\/li\u003e\n\u003cli\u003eTrusted by professional kitchens since 2020\u003c\/li\u003e\n\u003cli\u003eNext day delivery available\u003c\/li\u003e\n\u003cli\u003eCommercial parts specialists\u003c\/li\u003e\n\u003cli\u003eContact us if you need help finding the right part\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Robertshaw","offers":[{"title":"Default Title","offer_id":56010532094284,"sku":null,"price":80.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4857\/7612\/files\/Artboard6_f7a092d2-0abf-4cc1-a2cf-cb0939ab62a4.jpg?v=1763769082"},{"product_id":"robertshaw-thermostat-rx-2-24-for-gas-fryer-max-temp-203-c-npt-3-8","title":"Millivolt Fryer Thermostat 200-400F 3\/8 NPT RX-2-24 Commercial","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Robertshaw RX-2-24 is a millivolt-type control thermostat for commercial gas fryers. Providing temperature regulation between 200F and 400F (93C to 204C), it uses a snap-acting hydraulic mechanism to interrupt gas supply when the set temperature is reached. The RX-2-24 features a 24 inch capillary and a 3\/8 inch NPT stuffing gland with an 8mm bulb diameter. It is a widely recognised replacement that crosses to Vulcan Hart, Cecilware, Adcraft, Atosa and Star Manufacturing equipment among others. OEM references include Robertshaw 5300-402 and Atosa 301030004.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eType: Millivolt operating thermostat\u003c\/li\u003e\n\u003cli\u003eTemperature Range: 200F to 400F (93C to 204C)\u003c\/li\u003e\n\u003cli\u003eCapillary Length: 24 inches (610mm)\u003c\/li\u003e\n\u003cli\u003eBulb Diameter: 8mm\u003c\/li\u003e\n\u003cli\u003eBulb Length: 5.79 inches (147mm)\u003c\/li\u003e\n\u003cli\u003eTank Gland: 3\/8 inch NPT (18 threads)\u003c\/li\u003e\n\u003cli\u003eCross References: Robertshaw 5300-402, Atosa 301030004, Johnstone F16-899, CCC E-290, Cecilware L345A, Anets P8901-70, All Points 46-1183\u003c\/li\u003e\n\u003cli\u003eCondition: New\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCompatible Equipment\u003c\/h2\u003e\u003cp\u003eThis thermostat is compatible with the following commercial catering equipment:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAdcraft — deep fryer range (millivolt systems)\u003c\/li\u003e\n\u003cli\u003eAtosa — 301030004 series\u003c\/li\u003e\n\u003cli\u003eVulcan Hart — PMI 411506-8, 411506-13\u003c\/li\u003e\n\u003cli\u003eImperial — 0319 series, IF, IHR, IR\u003c\/li\u003e\n\u003cli\u003eDean — 11E, 11G, 14E, 14G, 32G, 714G, 1212G, 1414G, 1818G, 2020G, 2424G\u003c\/li\u003e\n\u003cli\u003eStar Manufacturing — 2T-Y9265\u003c\/li\u003e\n\u003cli\u003eCecilware \/ Commodore — L345A\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eNot sure if this fits your equipment? Contact us with your machine make, model and part number and we will confirm compatibility before you order.\u003c\/p\u003e\u003ch2\u003eSigns You Need To Replace This Part\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFryer oil temperature will not stabilise or runs consistently above the dial setting\u003c\/li\u003e\n\u003cli\u003eBurner does not fire or cuts out before oil reaches cooking temperature\u003c\/li\u003e\n\u003cli\u003eHigh-limit safety thermostat trips frequently due to temperature overshoot\u003c\/li\u003e\n\u003cli\u003eThermostat dial feels loose or stiff, or capillary shows visible damage or leaking\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhy Buy From LaunchCatering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUK stock - ready for fast dispatch\u003c\/li\u003e\n\u003cli\u003eTrusted by professional kitchens since 2020\u003c\/li\u003e\n\u003cli\u003eNext day delivery available\u003c\/li\u003e\n\u003cli\u003eCommercial parts specialists\u003c\/li\u003e\n\u003cli\u003eContact us if you need help finding the right part\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Robertshaw","offers":[{"title":"Default Title","offer_id":56019696746828,"sku":null,"price":80.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4857\/7612\/files\/1273810-large-01-09.jpg?v=1763812417"},{"product_id":"high-limit-safety-thermostat-232-c-450-f-npt-3-8","title":"High Limit Safety Thermostat 232C 450F 3\/8 NPT Manual Reset Fryer","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThis high limit safety thermostat provides overtemperature protection for commercial gas fryers, cutting off the gas supply when oil temperature reaches 232C (450F). Designed for use with a 3\/8 inch NPT stuffing gland, it is a universal-style replacement that fits a wide range of fryer brands including Atosa, Imperial, Royal Range, Anets, Infernus, KRD, Adexa and CaterBake. Cross-references include Robertshaw LCCM08036000 and several OEM part numbers across multiple brands. It features a manual reset to ensure the engineer positively resets the fryer after any overheat event.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eType: High limit safety thermostat with manual reset\u003c\/li\u003e\n\u003cli\u003eSwitch-Off Temperature: 232C (450F) fixed\u003c\/li\u003e\n\u003cli\u003eTank Gland: 3\/8 inch NPT\u003c\/li\u003e\n\u003cli\u003eCross References: Robertshaw LCCM08036000, Atosa 301030005, Imperial 1177, Royal Range 3112, Anets P8905-02, Tri-Star AS-300228, American Range A10040, Patriot PT-20101F004, Hamoki SP10050\u003c\/li\u003e\n\u003cli\u003eCondition: New\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCompatible Equipment\u003c\/h2\u003e\u003cp\u003eThis thermostat is compatible with the following commercial catering equipment:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAtosa — ref. 301030005\u003c\/li\u003e\n\u003cli\u003eImperial — 1177 series\u003c\/li\u003e\n\u003cli\u003eRoyal Range — 3112\u003c\/li\u003e\n\u003cli\u003eAnets — P8905-02\u003c\/li\u003e\n\u003cli\u003eAmerican Range — A10040\u003c\/li\u003e\n\u003cli\u003eTri-Star — AS-300228\u003c\/li\u003e\n\u003cli\u003ePatriot — PT-20101F004\u003c\/li\u003e\n\u003cli\u003eHamoki — SP10050\u003c\/li\u003e\n\u003cli\u003eInfernus — gas fryer range\u003c\/li\u003e\n\u003cli\u003eKRD — commercial fryer models\u003c\/li\u003e\n\u003cli\u003eAdexa — commercial fryer models\u003c\/li\u003e\n\u003cli\u003eCaterBake — commercial fryer models\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eNot sure if this fits your equipment? Contact us with your machine make, model and part number and we will confirm compatibility before you order.\u003c\/p\u003e\u003ch2\u003eSigns You Need To Replace This Part\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFryer trips out repeatedly during service even at normal operating temperatures\u003c\/li\u003e\n\u003cli\u003eOil overheats with no safety cut-out occurring - thermostat has failed open\u003c\/li\u003e\n\u003cli\u003eFryer will not heat up after a previous trip - manual reset has failed\u003c\/li\u003e\n\u003cli\u003eProbe or capillary shows corrosion, physical damage or leaking\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhy Buy From LaunchCatering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUK stock - ready for fast dispatch\u003c\/li\u003e\n\u003cli\u003eTrusted by professional kitchens since 2020\u003c\/li\u003e\n\u003cli\u003eNext day delivery available\u003c\/li\u003e\n\u003cli\u003eCommercial parts specialists\u003c\/li\u003e\n\u003cli\u003eContact us if you need help finding the right part\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Robertshaw","offers":[{"title":"Default Title","offer_id":56019995165004,"sku":null,"price":75.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4857\/7612\/files\/Artboard6_31e703ae-7192-4cb6-b49d-6740d83028cf.jpg?v=1763817970"},{"product_id":"218-c-auto-reset-overheat-thermostat-with-1-4-tank-gland","title":"Auto Reset High Limit Thermostat 218C 425F 1\/4 Gland Gas Fryer","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThis auto-reset overheat thermostat provides high limit safety protection for commercial gas fryers by automatically shutting off the appliance when oil temperature exceeds 218C (425F). Unlike manual reset versions, this thermostat automatically re-engages the circuit once the temperature drops back to a safe level, making it suitable for equipment where automatic recovery is designed into the control system. It features an 8mm probe, 940mm capillary tube, and a 1\/4 inch tank gland. It is a direct replacement for the Robertshaw reference LCCM21036000 and is widely used in Imperial CIFS-40 and CISF40 commercial fryer models.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eType: Auto reset overheat \/ high limit thermostat\u003c\/li\u003e\n\u003cli\u003eSwitch-Off Temperature: 218C (425F) fixed\u003c\/li\u003e\n\u003cli\u003eReset Type: Automatic\u003c\/li\u003e\n\u003cli\u003eProbe Diameter: 8mm\u003c\/li\u003e\n\u003cli\u003eCapillary Length: 940mm\u003c\/li\u003e\n\u003cli\u003eTank Gland: 1\/4 inch\u003c\/li\u003e\n\u003cli\u003eCross Reference: Robertshaw LCCM21036000\u003c\/li\u003e\n\u003cli\u003eCondition: New\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCompatible Equipment\u003c\/h2\u003e\u003cp\u003eThis thermostat is compatible with the following commercial catering equipment:\u003c\/p\u003e\u003cul\u003e\u003cli\u003eImperial — CIFS-40, CISF40 commercial fryer models\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eNot sure if this fits your equipment? Contact us with your machine make, model and part number and we will confirm compatibility before you order.\u003c\/p\u003e\u003ch2\u003eSigns You Need To Replace This Part\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFryer trips out during service and does not automatically restart as expected\u003c\/li\u003e\n\u003cli\u003eOil overheats with no cut-out occurring - thermostat has failed to operate\u003c\/li\u003e\n\u003cli\u003eAuto reset function is cycling repeatedly, indicating a temperature regulation problem\u003c\/li\u003e\n\u003cli\u003eProbe is corroded, bent, or the capillary shows signs of damage or leaking\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eAuto Reset vs Manual Reset — Key Difference\u003c\/h2\u003e\u003cp\u003eThis is an auto-reset thermostat, meaning once the oil temperature drops back to a safe level the circuit closes automatically without any manual intervention. Manual reset thermostats — such as the PP10084 or Henny Penny 16738 — require an engineer to press a reset button before the fryer will fire again. Always confirm which type your equipment uses before ordering: fitting a manual reset device in place of an auto-reset, or vice versa, will result in the fryer behaving incorrectly and could create a safety issue.\u003c\/p\u003e\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\u003cp\u003eDrain and cool the fryer completely before fitting. Remove the failed thermostat, feed the 8mm probe through the 1\/4 inch tank gland, and route the 940mm capillary without kinking. Fully tighten the gland and check for oil leaks before returning the fryer to service. Gas Safe registered engineer installation is strongly recommended for all commercial gas appliance repairs.\u003c\/p\u003e\u003ch2\u003eWhy Buy From LaunchCatering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUK stock - ready for fast dispatch\u003c\/li\u003e\n\u003cli\u003eTrusted by professional kitchens since 2020\u003c\/li\u003e\n\u003cli\u003eNext day delivery available\u003c\/li\u003e\n\u003cli\u003eCommercial parts specialists\u003c\/li\u003e\n\u003cli\u003eContact us if you need help finding the right part\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Robertshaw","offers":[{"title":"Default Title","offer_id":56020142653772,"sku":null,"price":75.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4857\/7612\/files\/0403264-large-01-38.jpg?v=1763819572"},{"product_id":"pitco-pp10084-hi-limit-thermostat-450f-npt-1-4","title":"High Limit Safety Thermostat 232C 450F 1\/4 NPT Manual Reset Fryer","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThis high limit safety thermostat is a direct replacement for Pitco PP10084 and protects commercial gas fryers from dangerous overheating by cutting off the gas supply when oil reaches 232C (450F). It is a manual reset device - after a safety trip the engineer must press the reset button to restore operation, ensuring that the cause of the overheat is investigated before the fryer is restarted. The thermostat features a 6.4mm x 120mm stainless steel probe, 30 inch (762mm) capillary, 1\/4 inch NPT stuffing gland, and 1 pole with 3 connections. It crosses to Robertshaw 5225-11B, Southbend 1199571, Anets PP10084, Frymaster 8073560, Imperial 32113 and MagiKitch'n 5047210 among others.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eType: High limit safety thermostat with manual reset\u003c\/li\u003e\n\u003cli\u003eSwitch-Off Temperature: 232C (450F) fixed\u003c\/li\u003e\n\u003cli\u003eProbe Diameter: 6.4mm\u003c\/li\u003e\n\u003cli\u003eProbe Length: 120mm\u003c\/li\u003e\n\u003cli\u003eCapillary Length: 30 inches (762mm)\u003c\/li\u003e\n\u003cli\u003eTank Gland: 1\/4 inch NPT\u003c\/li\u003e\n\u003cli\u003eConnections: 1 pole, 3 connections\u003c\/li\u003e\n\u003cli\u003ePitco Part Number: PP10084 \/ P5047210\u003c\/li\u003e\n\u003cli\u003eCross References: Robertshaw 5225-11B \/ LCHM0503000000, Southbend 1199571, Anets PP10084, Imperial 32113, Frymaster 8073560, Globe U03991290101, MagiKitch'n 5047210 \/ 10084, All Points 48-1006\u003c\/li\u003e\n\u003cli\u003eCondition: New\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCompatible Equipment\u003c\/h2\u003e\u003cp\u003eThis thermostat is compatible with the following commercial catering equipment:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePitco — SG14, SG14R, SG14S, SG14T, SG14TS, SG14RS, SG14RDI, SG14DI, SG14SD\u003c\/li\u003e\n\u003cli\u003ePitco — SG18, SG18S, SG18F, SG18DI, SG18SD, SG18-JS\u003c\/li\u003e\n\u003cli\u003ePitco — SSH55, SSH60, SSH75RS, SSHLV14, SSHLV184\u003c\/li\u003e\n\u003cli\u003ePitco — VF35, VF65, MGII, 35C+, 45C+, 65C+, SGC, SGF18, SGH50, SGM24, SGM34, SGM1824\u003c\/li\u003e\n\u003cli\u003ePitco — E500D, E400T, E400, 18S, 18, 18WKS, 24RUFM, SRTG14, RTG14, RTE14\u003c\/li\u003e\n\u003cli\u003ePitco — SFSG14, SFSG14C-S, SFSG14R, SFSG14RS, SFSG14S, SFSG14T, SFSG14TS, SFSG18, SFSG18S\u003c\/li\u003e\n\u003cli\u003ePitco — LJFBG18, LJFBG24, LJFBGD18, LJFBGD24, CKSSH55C, CKSSH60WC, BKSSH60W\u003c\/li\u003e\n\u003cli\u003eSouthbend Range — 1199571 compatible models\u003c\/li\u003e\n\u003cli\u003eAnets — PP10084 compatible models\u003c\/li\u003e\n\u003cli\u003eImperial — 32113 compatible models\u003c\/li\u003e\n\u003cli\u003eFrymaster — 8073560 compatible models\u003c\/li\u003e\n\u003cli\u003eMagiKitch'n — 5047210 \/ 10084 compatible models\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eNot sure if this fits your equipment? Contact us with your machine make, model and part number and we will confirm compatibility before you order.\u003c\/p\u003e\u003ch2\u003eSigns You Need To Replace This Part\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh limit trips during normal frying service and requires repeated resetting\u003c\/li\u003e\n\u003cli\u003eOil overheats past 232C with no safety cut-out - thermostat has failed to operate\u003c\/li\u003e\n\u003cli\u003eFryer will not heat at all after a previous trip and the reset button will not latch\u003c\/li\u003e\n\u003cli\u003eProbe shows corrosion, the capillary is damaged, or there is oil leaking from the stuffing gland\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhy Buy From LaunchCatering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUK stock - ready for fast dispatch\u003c\/li\u003e\n\u003cli\u003eTrusted by professional kitchens since 2020\u003c\/li\u003e\n\u003cli\u003eNext day delivery available\u003c\/li\u003e\n\u003cli\u003eCommercial parts specialists\u003c\/li\u003e\n\u003cli\u003eContact us if you need help finding the right part\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Robertshaw","offers":[{"title":"Default Title","offer_id":56020156842316,"sku":null,"price":75.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4857\/7612\/files\/Artboard8_b5d369dc-3110-48a3-b1c0-1e002aed1665.jpg?v=1763820191"},{"product_id":"robertshaw-1830-002-5chl-6-pilot-uni-kit-90-left-hand-commercial-gas-oven-fryer","title":"Robertshaw 1830-002 Pilot Burner 5CHL-6 90° Left-Hand Flame For Commercial Gas Oven \u0026 Fryer","description":"\u003ch2\u003eRobertshaw 1830-002 Pilot Uni-Kit (5CHL-6) — 90° Left-Hand Flame | Commercial Gas Oven \u0026amp; Fryer Pilot\u003c\/h2\u003e\n\u003cp\u003eThe Robertshaw 1830-002 is a genuine OEM 1830 Series Pilot Uni-Kit® engineered for gas-fired commercial catering equipment including ovens, fryers, chargrills, ranges, and incinerators. This aerated, non-linting channel pilot delivers a reliable \u003cstrong\u003e90° left-hand flame pattern\u003c\/strong\u003e — the mirror counterpart to the 1830-003 right-hand model. Compatible with all Robertshaw® and most competitive thermocouple and thermopile systems. The included Uni-Kit adaptor converts threaded 2CH thermocouple\/thermopile connections to snap-in 2C type.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number:\u003c\/strong\u003e 1830-002\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory \/ OEM Part Number:\u003c\/strong\u003e 5CHL-6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlt Part Numbers:\u003c\/strong\u003e 5CL-6 • 76431 (Robertshaw) • 63885 (Uni-Line)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSKU:\u003c\/strong\u003e LC-RS-1830-002\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Application:\u003c\/strong\u003e 2CH \u0026amp; 2C Incinerator-Target Pilot Uni-Kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame Pattern:\u003c\/strong\u003e 90° LEFT-Hand — \u003cem\u003eorder LC-RS-1830-003 if right-hand is required\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHood Type:\u003c\/strong\u003e 5 • \u003cstrong\u003eMounting Bracket:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Natural Gas (LP orifice included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTube Connection:\u003c\/strong\u003e 1\/4 inch CCT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouple:\u003c\/strong\u003e 2CH threaded and 2C snap-in (adaptor included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePilot Type:\u003c\/strong\u003e Aerated, non-linting, incinerator-target\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New — genuine Robertshaw OEM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Equipment \u0026amp; Full Cross-Reference\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eImperial\u003c\/strong\u003e — Part 316 (commercial ranges, ovens, chargrills)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJohnson Controls\u003c\/strong\u003e — J993MDA-2, J997MDA-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eITT \/ General Control\u003c\/strong\u003e — 26T0205TV018\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhite-Rodgers\u003c\/strong\u003e — E37\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUni-Line\u003c\/strong\u003e — 63885\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobertshaw OEM codes:\u003c\/strong\u003e 5CHL-6, 5CL-6, 76431\u003c\/li\u003e\n\u003cli\u003eCommercial gas ovens, fryers, ranges, chargrills and incinerators with Robertshaw 2C\/2CH thermocouple or thermopile gas control systems requiring a \u003cstrong\u003eleft-hand 90° flame\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLeft-Hand vs Right-Hand — Why It Matters\u003c\/h3\u003e\n\u003cp\u003ePilot flame direction determines which side of the thermocouple tip is heated. Fitting the wrong orientation causes weak thermocouple signal and intermittent pilot lockout. Always confirm before ordering:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1830-002 \/ LC-RS-1830-002\u003c\/strong\u003e — 90° LEFT-Hand — \u003cstrong\u003ethis product\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1830-003 \/ LC-RS-1830-003\u003c\/strong\u003e — 90° RIGHT-Hand — see separate listing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAerated non-linting design — no air shutters required\u003c\/li\u003e\n\u003cli\u003eHorizontal or vertical gas inlet options\u003c\/li\u003e\n\u003cli\u003eNatural gas orifice factory-installed; LP orifice included\u003c\/li\u003e\n\u003cli\u003eUni-Kit adaptor (2CH to 2C) included\u003c\/li\u003e\n\u003cli\u003eGenuine Robertshaw OEM product\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy from LaunchCatering?\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e✔ Flame orientation clearly stated — preventing wrong-part orders\u003c\/li\u003e\n\u003cli\u003e✔ Full cross-reference: Imperial 316, J993MDA-2\/J997MDA-2, ITT 26T0205TV018, White-Rodgers E37\u003c\/li\u003e\n\u003cli\u003e✔ UK stock — order before 4pm for next working day despatch\u003c\/li\u003e\n\u003cli\u003e✔ Trusted UK catering spare parts supplier — LaunchCatering Ltd\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eUK Stock. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e SKU: LC-RS-1830-002 • Part: 1830-002 \/ 5CHL-6 • 90° LEFT-Hand flame.\u003c\/em\u003e\u003c\/p\u003e","brand":"Robertshaw","offers":[{"title":"Natural Gas(NG)","offer_id":57634133147980,"sku":"LC-RS-1830-002","price":25.0,"currency_code":"GBP","in_stock":true},{"title":"LPG","offer_id":57634133180748,"sku":"LC-RS-1830-003","price":25.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4857\/7612\/files\/LC-RS-1830-002.jpg?v=1778328599"},{"product_id":"robertshaw-1830-111-commercial-gas-pilot-burner-2chl-1","title":"Robertshaw 1830-111 Commercial Gas Pilot Burner 2CHL-1","description":"\u003ch2\u003eAbout This Part\u003c\/h2\u003e\u003cp\u003eThe Robertshaw 1830-111 is an aerated incinerator-target commercial gas pilot burner with a 25 degree left hand twin flame for standing pilot ignition systems on a wide range of commercial catering equipment. A Uni-Kit design compatible with both 1820 and 1830 series thermocouple systems via an included adapter and supplied with natural gas and LP gas orifices for complete on-site installation flexibility.\u003c\/p\u003e\u003ch2\u003eKey Specifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eManufacturer Part Number: 1830-111\u003c\/li\u003e\n\u003cli\u003eFactory Part Number: 2CHL-1\u003c\/li\u003e\n\u003cli\u003eSeries: 1830 Pilot Uni-Kit Incinerator-Target Type\u003c\/li\u003e\n\u003cli\u003eMounting Bracket: Type 1\u003c\/li\u003e\n\u003cli\u003eHood Type: 2 Twin Flame\u003c\/li\u003e\n\u003cli\u003eFlame Pattern: 25 Degree Left Hand\u003c\/li\u003e\n\u003cli\u003eGas Type: Natural Gas and LP Gas\u003c\/li\u003e\n\u003cli\u003eTubing Size: 1\/4 Inch\u003c\/li\u003e\n\u003cli\u003eThermocouple Connection: 2CH Threaded converts to 2C Snap-In via included adapter\u003c\/li\u003e\n\u003cli\u003eThermocouple and Thermopile Compatible\u003c\/li\u003e\n\u003cli\u003eReplaces Both 1820 and 1830 Series Applications\u003c\/li\u003e\n\u003cli\u003eAerated Non-Linting Pilot Design\u003c\/li\u003e\n\u003cli\u003eCondition: New\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCompatible Equipment\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGarland - Commercial Gas Ranges and Ovens requiring Bracket Type 1 pilot\u003c\/li\u003e\n\u003cli\u003eVulcan Hart - Commercial Gas Ranges and Ovens requiring Bracket Type 1 pilot\u003c\/li\u003e\n\u003cli\u003eSouthbend - Commercial Gas Ranges and Ovens\u003c\/li\u003e\n\u003cli\u003eBlodgett - Commercial Gas Ovens\u003c\/li\u003e\n\u003cli\u003eImperial - Commercial Gas Cooking Equipment\u003c\/li\u003e\n\u003cli\u003eAscaso - Commercial Cooking Appliances\u003c\/li\u003e\n\u003cli\u003eStar Manufacturing - Commercial Gas Equipment\u003c\/li\u003e\n\u003cli\u003eAll equipment using Mounting Bracket Type 1 with 2C or 2CH thermocouple or thermopile system\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOEM Cross-References\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRobertshaw Legacy: 27904 and 27-904\u003c\/li\u003e\n\u003cli\u003eRobertshaw: 2CHL-1 and 2CL-1\u003c\/li\u003e\n\u003cli\u003eUni-Line: 1820-104 and 1820-105 and 1820-111\u003c\/li\u003e\n\u003cli\u003eUni-Line: 1830-104 and 1830-105 and 1830-C003 and 64001\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e25 degree left hand flame pattern positions pilot flame directly onto thermocouple tip for reliable safety valve operation\u003c\/li\u003e\n\u003cli\u003eHood Type 2 twin flame provides enhanced main burner ignition performance\u003c\/li\u003e\n\u003cli\u003eMounting Bracket Type 1 for correct mechanical fitment on all listed compatible equipment\u003c\/li\u003e\n\u003cli\u003eSeven confirmed Uni-Line cross-references spanning 1820 and 1830 series legacy commercial equipment\u003c\/li\u003e\n\u003cli\u003eNatural gas and LPG orifices both included for full on-site gas type flexibility\u003c\/li\u003e\n\u003cli\u003eAerated non-linting design prevents orifice blockage in high-use commercial kitchens\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eImportant Orientation Note\u003c\/h2\u003e\u003cp\u003eThis is the LEFT HAND 25 degree flame variant with Mounting Bracket Type 1. Always verify bracket type and flame orientation from the equipment service manual before ordering. Incorrect bracket type prevents correct mounting. Incorrect flame orientation causes thermocouple underheating and gas valve safety lockout. The right hand equivalent for Bracket Type 1 is the Robertshaw 1830-112.\u003c\/p\u003e\u003ch2\u003eWhy Buy From LaunchCatering\u003c\/h2\u003e\u003cp\u003eLaunchCatering is a trusted UK supplier of commercial catering spare parts. UK stock is held for fast dispatch and every listing carries full OEM cross-reference data across both 1820 and 1830 series applications. With seven confirmed cross-references this is a high-frequency legacy service part held ready for immediate dispatch.\u003c\/p\u003e\u003cp\u003eIn stock now. Order before 2pm Monday to Friday for next-day UK delivery. Contact us to verify compatibility before ordering.\u003c\/p\u003e","brand":"Robertshaw","offers":[{"title":"Default Title","offer_id":57502202495308,"sku":"LC-RS-1830-111","price":25.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4857\/7612\/files\/LC-RS-1830-111-1.jpg?v=1778420856"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4857\/7612\/collections\/Imperial-8.png?v=1773536561","url":"https:\/\/launchcatering.com\/collections\/imperial.oembed","provider":"LAUNCHCATERING LTD","version":"1.0","type":"link"}