{"product_id":"robertshaw-1830-601-commercial-gas-pilot-burner-2c-2-reversed-hood","title":"Robertshaw 1830-601 Commercial Gas Pilot Burner 2C-2 Reversed Hood Bracket 2","description":"\u003ch2\u003eAbout This Part\u003c\/h2\u003e\u003cp\u003eThe Robertshaw 1830-601 is an aerated incinerator-target commercial gas pilot burner with a reversed hood configuration for thermocouple-only standing pilot systems on specific Garland ovens and Vulcan Hart ranges. The hood is fitted in the reverse orientation directing the flame away from the thermocouple tip as required by the original equipment design. Supplied with both natural gas and LP gas orifices using the same 26-1554 orifice for both gas types.\u003c\/p\u003e\u003ch2\u003eKey Specifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eManufacturer Part Number: 1830-601\u003c\/li\u003e\n\u003cli\u003eFactory Part Number: 2C-2\u003c\/li\u003e\n\u003cli\u003eSeries: 1830 Pilot Uni-Kit Incinerator-Target Type\u003c\/li\u003e\n\u003cli\u003eMounting Bracket: Type 2\u003c\/li\u003e\n\u003cli\u003eHood Type: 2 Twin Flame\u003c\/li\u003e\n\u003cli\u003eFlame Pattern: Standard with Reversed Hood Configuration\u003c\/li\u003e\n\u003cli\u003eThermocouple Compatibility: Thermocouple ONLY - Not Compatible with Thermopiles\u003c\/li\u003e\n\u003cli\u003eGas Type: Natural Gas and LP Gas\u003c\/li\u003e\n\u003cli\u003eTubing Size: 1\/4 Inch\u003c\/li\u003e\n\u003cli\u003eGas Orifice: 26-1554 for both Natural Gas and LP Gas\u003c\/li\u003e\n\u003cli\u003eAerated Non-Linting Pilot Design\u003c\/li\u003e\n\u003cli\u003eCondition: New\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCompatible Equipment\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGarland - Commercial Gas Ovens (OEM Ref: 27330 and G0526-1)\u003c\/li\u003e\n\u003cli\u003eVulcan Hart - Series 7800 Commercial Gas Ranges (OEM Ref: 00-409839-00001 and 409839-01)\u003c\/li\u003e\n\u003cli\u003eVulcan Hart - GH GHM GHX and GHXM Commercial Gas Ranges\u003c\/li\u003e\n\u003cli\u003eHobart - Commercial Cooking Equipment (OEM Ref: 409839-1 and 409839-01)\u003c\/li\u003e\n\u003cli\u003eViscount - Commercial Cooking Appliances\u003c\/li\u003e\n\u003cli\u003eAll equipment specifying Mounting Bracket Type 2 reversed hood 2C-2 pilot with thermocouple-only system\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOEM Cross-References\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGarland: 27330 and G0526-1\u003c\/li\u003e\n\u003cli\u003eHobart Corp: 409839-1 and 409839-01 and 409839-00001 and VH409839-1\u003c\/li\u003e\n\u003cli\u003eVulcan Hart: 00-409839-00001 and 409839-01 and 409839-03 and VH109839-1\u003c\/li\u003e\n\u003cli\u003eConsolidated Comm.Co: M-117\u003c\/li\u003e\n\u003cli\u003eUni-Line: 1830-C007 and 63028 and CD2376-64\u003c\/li\u003e\n\u003cli\u003eRobertshaw Variant: 1830-60A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eReversed hood configuration directs flame in the specific orientation required by Garland oven and Vulcan Hart range designs\u003c\/li\u003e\n\u003cli\u003eHood Type 2 twin flame for reliable main burner ignition performance\u003c\/li\u003e\n\u003cli\u003eMounting Bracket Type 2 for correct mechanical fitment on all listed compatible equipment\u003c\/li\u003e\n\u003cli\u003eSame 26-1554 orifice used for both natural gas and LP gas eliminating orifice swap on conversion\u003c\/li\u003e\n\u003cli\u003eAerated non-linting head prevents orifice blockage in commercial cooking environments\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCritical Engineering Notes\u003c\/h2\u003e\u003cp\u003eREVERSED HOOD: The flame hood on this model points away from the thermocouple rather than towards it. This is correct for specific Garland oven and Vulcan Hart range configurations. Fitting a standard-hood pilot in place of this part will cause thermocouple underheating and gas valve safety lockout. Always inspect the existing pilot to confirm hood orientation before ordering.\u003c\/p\u003e\u003cp\u003eTHERMOCOUPLE ONLY: This pilot cannot be used with thermopile sensing systems. Verify that the gas valve is operated by a thermocouple millivolt system before ordering. If a two-wire thermopile system is fitted a different pilot model is required.\u003c\/p\u003e\u003ch2\u003eWhy Buy From LaunchCatering\u003c\/h2\u003e\u003cp\u003eLaunchCatering is a trusted UK supplier of commercial catering spare parts. UK stock is held for fast dispatch and every listing carries full OEM cross-reference data and clearly published engineering warnings. We are the only UK supplier to publish the reversed hood configuration and thermocouple-only restriction for this part removing all ordering ambiguity for commercial gas engineers.\u003c\/p\u003e\u003cp\u003eIn stock now. Order before 2pm Monday to Friday for next-day UK delivery. Contact us to verify compatibility before ordering.\u003c\/p\u003e","brand":"Robertshaw","offers":[{"title":"Default Title","offer_id":57502203969868,"sku":"LC-RS-1830-601","price":25.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4857\/7612\/files\/LC-RS-1830-601-1.jpg?v=1778421040","url":"https:\/\/launchcatering.com\/products\/robertshaw-1830-601-commercial-gas-pilot-burner-2c-2-reversed-hood","provider":"LAUNCHCATERING LTD","version":"1.0","type":"link"}